Danfoss 014G2480 control via MQTT |
Integrate your Danfoss 014G2480 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2025-01-03 12:11:48 -0800 |
device-page |
Model | 014G2480 |
Vendor | Danfoss |
Description | Temperature and humidity sensor |
Exposes | battery, temperature, humidity, voltage, linkquality |
Picture |
This device supports OTA updates, for more information see OTA updates.
How to use device type specific configuration
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Remaining battery in %, can take up to 24 hours before reported.
Value can be found in the published state on the battery
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Measured temperature value.
Value can be found in the published state on the temperature
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Voltage of the battery in millivolts.
Value can be found in the published state on the voltage
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is mV
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.