Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathmodbus_task.c
133 lines (112 loc) · 3.71 KB
/
modbus_task.c
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
#include <stdio.h>
#include <stdlib.h>
#include "modbus_task.h"
#include "nanomodbus.h"
#include "platform.h"
#include "config.h"
#include "utilis.h"
#define MAX_CONN_ATTEMPS 10
unsigned long shared_value = 0;
pthread_mutex_t mutex = PTHREAD_MUTEX_INITIALIZER;
pthread_cond_t cond = PTHREAD_COND_INITIALIZER;
// This task read a holding register, send it to mqtt task, increment and send it back to the plc.
// Connect
// connected ? no -> connect
// connected
// read register
// send task notification to mqtt task
// increment plc data
// send new data to plc
// check if i need to disconnect and exit
void *modbus_task(void *arg)
{
modbus_task_config_t *config = (modbus_task_config_t *)arg;
if(config == NULL)
{
// No config
fprintf(stderr, "modbus_task: Error no config!\n");
pthread_exit(NULL);
return NULL;
}
int nAttemps = 0;
void *conn = NULL;
do
{
// Set up the TCP connection
conn = connect_tcp(config->plc_ip, config->plc_port);
if (!conn)
{
fprintf(stderr, "modbus_task: [%d] Error connecting to server retry...\n", nAttemps++);
}
else
{
break;
}
} while (nAttemps < MAX_CONN_ATTEMPS);
if (!conn)
{
fprintf(stderr, "modbus_task: Error connecting to server\n");
return NULL;
}
nmbs_platform_conf platform_conf;
platform_conf.transport = NMBS_TRANSPORT_TCP;
platform_conf.read = read_fd_linux;
platform_conf.write = write_fd_linux;
platform_conf.arg = conn; // Passing our TCP connection handle to the read/write functions
// Create the modbus client
nmbs_t nmbs;
nmbs_error err = nmbs_client_create(&nmbs, &platform_conf);
if (err != NMBS_ERROR_NONE)
{
fprintf(stderr, "modbus_task: Error creating modbus client\n");
if (!nmbs_error_is_exception(err))
{
return NULL;
}
}
// Set only the response timeout. Byte timeout will be handled by the TCP connection
nmbs_set_read_timeout(&nmbs, 1000);
do
{
// Read holding register
uint16_t r_regs[1];
err = nmbs_read_holding_registers(&nmbs, config->plc_register, 1, r_regs);
if (err != NMBS_ERROR_NONE)
{
fprintf(stderr, "modbus_task: Error reading holding register at address %d - %s\n", config->plc_register, nmbs_strerror(err));
if (!nmbs_error_is_exception(err))
{
disconnect(conn);
continue; // check while condition
}
}
printf("modbus_task: Register at address %d: %d\n", config->plc_register, r_regs[0]);
// Send register to mqtt task
pthread_mutex_lock(&mutex);
shared_value = r_regs[0];
pthread_cond_signal(&cond);
pthread_mutex_unlock(&mutex);
//printf("Send data [%d] to mqtt task", r_regs[0]);
// Increment data
++r_regs[0];
// Write data in holding register
uint16_t w_regs[1] = {r_regs[0]};
err = nmbs_write_multiple_registers(&nmbs, config->plc_register, 1, w_regs);
if (err != NMBS_ERROR_NONE)
{
fprintf(stderr, "modbus_task: Error writing register at address %d - %s\n", config->plc_register, nmbs_strerror(err));
if (!nmbs_error_is_exception(err))
{
disconnect(conn);
continue; // check while condition
}
}
// wait some time
sleep_ms(1000);
// check if an error occurred or i need disconnect
} while (err == NMBS_ERROR_NONE && 1);
// Close the TCP connection
disconnect(conn);
// No need to destroy the nmbs instance, bye bye
return NULL;
}