My server is a Dell R730xd with iDRAC 8 and the way the script reads CPU temperatures will perhaps work for a SuperMicro IPMI, but not for a iDRAC 8 setup.
iDRAC only has a "Temp" entry per CPU. Not even "CPU 0 TEMP", just Temp.
So, in my server, a dual socket with only one occupied, the script shows this when using ipmi:
=== CPU (0) ===
[: : bad number
CPU 1: [C]
[: : bad number
CPU 0: [C]
When run part of the line from the script it shows this:
$ doas ipmitool -I lanplus -H 10.42.10.10 -U root -f /root/ipmi_password sdr elist all | grep Temp
Inlet Temp | 04h | ok | 7.1 | 24 degrees C
Exhaust Temp | 01h | ok | 7.1 | 33 degrees C
Temp | 0Eh | ok | 3.1 | 43 degrees C
Temp | 0Fh | ns | 3.2 | Disabled
The second Temp line is the second socket which is not used in my server.
Oddly enough, the iDRAC Temp is higher then what sysctl shows, but I am guessing iDRAC shows the package temperature and not some combined/divided temperature.
$ sh get_hdd_temp.sh
=== CPU (16) ===
CPU 0: 37C
CPU 1: 38C
CPU 2: 38C
CPU 3: 38C
CPU 4: 37C
CPU 5: 37C
CPU 6: 36C
CPU 7: 36C
CPU 8: 37C
CPU 9: 38C
CPU 10: 36C
CPU 11: 37C
CPU 12: 38C
CPU 13: 39C
CPU 14: 36C
CPU 15: 36C
I checked with sysctl but there doesn't seem to be a package temperature available.
It would be nice to have iDRAC support.
I can deliver a full "sdr elist all" if wanted. It's rather long.
The text was updated successfully, but these errors were encountered:
My server is a Dell R730xd with iDRAC 8 and the way the script reads CPU temperatures will perhaps work for a SuperMicro IPMI, but not for a iDRAC 8 setup.
iDRAC only has a "Temp" entry per CPU. Not even "CPU 0 TEMP", just Temp.
So, in my server, a dual socket with only one occupied, the script shows this when using ipmi:
When run part of the line from the script it shows this:
The second Temp line is the second socket which is not used in my server.
Oddly enough, the iDRAC Temp is higher then what sysctl shows, but I am guessing iDRAC shows the package temperature and not some combined/divided temperature.
I checked with sysctl but there doesn't seem to be a package temperature available.
It would be nice to have iDRAC support.
I can deliver a full "sdr elist all" if wanted. It's rather long.