forked from AllenInstitute/MIES
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathUserConfig - Template.txt
143 lines (74 loc) · 3.07 KB
/
UserConfig - Template.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
####### Please enter User Configurations for MIES Devices #######
Version= 1
####### Load/Save Directories #######
Save data to = D:MiesSave
Stim set file name = C:\MiesHDF5Files\SavedStimSets\StimSet.nwb
####### Device Settings #######
Name of ITC Device = ITC1600
ITC Device number = 0
Enable multiple ITC devices = Yes
Respect ITI for manual initialization = Yes
####### Amplifier and Pressure Settings #######
#### Force position of MCCs to one of the following monitors: Upper Right, Lower Right, Upper Left, Lower Left. May be left to - none - and MCCs will open in place ####
Position MCCs = - none -
#### Separate headstages on the same amplifier with ',' and separate headstages on different amplifiers with ';' (ex. 0,1;2,3;...) ####
Amplifier Names = 0,1;2,3;4,5;6,7
#### List active headstages separated by ';' ####
Active headstages = 0;1;2;3;4;5;6;7
#### Separate serial numbers and pressure device names with ';' ####
Amplifier Serial Numbers = 836760;836761;836782;836783
Name of Pressure Devices = Pressure1and2;Pressure3and4;Pressure5and6;Pressure7and8
#### Separate calibration constants with ';'. Negative constants are assumed to be equal and opposite to positive constants ####
Positive Pressure Calibration Constants = 0.4;0.14;0.05;0.14;0.29;0.03;0.05;0.045
####### Async Settings #######
Asyncronous channel 0 = Set Temperature
Asyncronous channel 1 = Bath Temperature
Asyncronous Unit = degC
Temperature control gain (in V) = 0.01
Maximum Temperature Allowed (in degrees C) = 34
Minimum Temperature Allowed (in degrees C) = -1
######## Patching Settings ######
In bath pressure (psi) = 0.5
Initial Seal Pressure (psi) = -0.1
Maximum Seal Pressure (psi) = -1.4
Enter User Pressure Mode for Sealing = Yes
Prevent User Pressure Mode from following headstage = Yes
Initial Holding Potential = -70
Enable I-clamp Autobias = Yes
I-clamp Autobias range (mV) = 1
I-clamp Max bias current (pA) = 500
Capacitance Neutralization enabled = No
### User pressure entries ###
Name of User Pressure Device = Dev1
User Pressure Device ADC = 0
######## Test Pulse Settings ######
Activate TP after DAQ = Yes
Save each TP sweep = No
TP Amplitude in VC = -10
TP Amplitude in IC = -50
Baseline % = 30
######## Data Saving Settings ######
Export to NWB = Yes
Append Asynchronous reading to wave note = Yes
Sync MIES to MCC = Yes
Save amplifier settings = Yes
Require amplifier connection to active headstage = Yes
###### Data Acquisition Settings ######
Switch clamp modes via I equal zero = Yes
Enable repeated acquisition = Yes
Number of stimulus set repeats = 5
Get stimulus set ITI = No
Default ITI (ms) = 15
Enable ooDAQ = Yes
ooDAQ post sweep delay (ms) = 150
User onset delay (ms) = 500
Termination delay (ms) = 1000
Skip analysis function calls = Yes
Decimation method = MinMax
Decimation factor = -1
###### Initial stimulus parameters apply to all channels ######
Initial stim set VC = PulseTrain_20Hz_DA_0
Initial stim set amplitude VC = 70
Initial stim set IC = PulseTrain_20Hz_DA_0
Initial stim set amplitude IC = 1500
Enable stim set mode switch = Yes