This is the primary tracking issue for integrating Celeritas with the simulation workflow for the LUX-ZEPLIN experiment. The primary Celeritas contact points are the "assignees" to the right.
LZ currently uses optical maps due to prohibited cost of inline optical tracking (Would very much like to do optical photons inline to the veto detectors.)
Three detectors LZ: inner TPC, skin, outer detector
Optical maps are done for the inner TPC (top 5-10cm), 1cm voxels for a total 15 billion photons (ish): 10 nodes * 256 threads -> 24 hours wall time
Record hits and time on PMT surfaces (no direction, no position)
Run geant4 in 2 modes: energy deposit (no optical photons), then PMT output (using optical map). - BACCARAT requires Geant4 10.3
This is the primary tracking issue for integrating Celeritas with the simulation workflow for the LUX-ZEPLIN experiment. The primary Celeritas contact points are the "assignees" to the right.
Core capabilities