# Version 2.2
NR_OF_BATTERIES = 2 # Nr. of physical batteries to be aggregated
NR_OF_MPPTS = 1 # Nr. of MPPTs
BATTERY_KEY_WORD = 'com.victronenergy.battery.tty' # Key world to identify services of physical Serial Batteries
BATTERY_NAME_KEY_WORD = 'SerialBattery' # Key world to identify the name of batteries (to exclude SmartShunt)
BATTERY_NAME_PATH = '/CustomName' # What defines the battery name
#BATTERY_NAME_PATH = '/HardwareVersion'
MULTI_KEY_WORD = 'com.victronenergy.vebus.tty' # Key world to identify service of Multis/Quattros (or cluster of them)
MPPT_KEY_WORD = 'com.victronenergy.solarcharger.tty' # Key world to identify services of solar chargers (RS not tested, only SmartSolar)
SMARTSHUNT_NAME_KEY_WORD = 'SmartShunt' # Key world to identify services of SmartShunt (not tested)
SEARCH_TRIALS = 10 # Trials to identify of all batteries before exit and restart
READ_TRIALS = 10 # Trials to get consistent data of all batteries before exit and restart
CURRENT_FROM_VICTRON = True # If True, the current measurement by Multis/Quattros and MPPTs is taken instead of BMS
DC_LOADS = False # If DC loads with Smart Shunt present, can be used for total current measurement
INVERT_SMARTSHUNT = False # False: Current subtracted, True: Current added
OWN_SOC = True # If True, the self calculated charge indicators are taken instead of BMS
CHARGE_SAVE_PRECISION = 0.0025 # Trade-off between save precision and file access frequency
OWN_CHARGE_PARAMETERS = True # Calculate own charge/discharge control parameters (True) from following settings
# or use them from battery driver (False)
CHARGE_VOLTAGE = 2.5 # Constant voltage charge = this value * nr. of cells
MAX_CELL_VOLTAGE = 2.53 # If reached by 1-st cell, the charger voltage is clamped to the measured value
DISCHARGE_VOLTAGE = 2.0 # If reached, discharge current set to zero
MIN_CELL_VOLTAGE = 1.9 # If reached, discharge current set to zero
VOLTAGE_SET_PRECISION = 0.04 # To be subtracted from the calculated max. charge voltage if MAX_CELL_VOLTAGE is exceeded
MAX_CHARGE_CURRENT = 300 # Max. charge current at normal conditions
MAX_DISCHARGE_CURRENT = 200 # Max. discharge current at normal conditions
# settings limiting charge and discharge current if at least one cell gets full or empty
# the lists may have any length, but the same length for voltage and current
# linear interpolation is used for values between
CELL_FULL_LIMITING_VOLTAGE = [CHARGE_VOLTAGE - 0.1, CHARGE_VOLTAGE, MAX_CELL_VOLTAGE] # [min, .... ,max]
CELL_FULL_LIMITED_CURRENT = [1, 0.05, 0]
CELL_EMPTY_LIMITING_VOLTAGE = [DISCHARGE_VOLTAGE - 0.1, DISCHARGE_VOLTAGE, MIN_CELL_VOLTAGE] # [min, .... ,max]
CELL_EMPTY_LIMITED_CURRENT = [0, 0.05, 1]
LOGGING = 2 # 0: no logging, 1: print to console, 2: print to file
LOG_VOLTAGE_CHANGE = 0.1 # change of max. charge voltage to be logged
LOG_CURRENT_CHANGE = 5 # change of max. charge/discharge current to be logged