Article: Q261874
Product(s): Microsoft Systems Management Server
Version(s): winnt:2.0,2.0 SP1,2.0 SP2
Operating System(s):
Keyword(s): kbsms200
Last Modified: 17-MAY-2000
-------------------------------------------------------------------------------
The information in this article applies to:
- Microsoft Systems Management Server versions 2.0, 2.0 SP1, 2.0 SP2
-------------------------------------------------------------------------------
SYMPTOMS
========
Systems Management Server (SMS) LAN Sender may generate connection failure
messages connecting to child sites. When this occurs, the Sender.log file
states:
Error during WNetAddConnection2 to \\Server\SMS_SITE (487).
This does not prevent connectivity between LAN Sender and the child sites.
CAUSE
=====
This error message can occur on the SMS site server if you are using version 4.7
of the NetWare redirector and a drive is mapped to a NetWare resource.
RESOLUTION
==========
Upgrade to a supported version of the NetWare redirector as defined in the
Release Notes included with your version of the SMS service pack.
Additional query words: prodsms intranetware netware
======================================================================