Notifications
You must be signed in to change notification settings - Fork 5
/
Copy pathSchneiderElectric_iEM3255.py
492 lines (437 loc) · 16.9 KB
/
SchneiderElectric_iEM3255.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
#!/usr/bin/python
# coding: utf-8
# Copyright 2017 Luca Berton
__author__ = 'lucab85'
import sys
from ModbusWrapperClient import ModbusWrapperClient
from settings import PATH_PM_SCHNEIDERELECTRICIEM3255, PM_settings, PM_config
import math
import datetime
from logmanagement import logmanagement
log = logmanagement.getlog('SchneiderElectriciEM3255', 'powermeter').getLogger()
class SchneiderElectric_iEM3255():
def __init__(self, PM_modbusHost, PM_modbusPort, PM_modbusAddress, PM_startReg, PM_maxRegsRead,
PM_timeout, PM_endian, PM_modbusAddressoffset=0, PM_cacheEnabled=False, PM_base_commands=0):
self.mb = ModbusWrapperClient(PM_modbusAddress, PM_maxRegsRead, PM_timeout, PM_endian)
self.PM_addressoffset = PM_modbusAddressoffset
self.mb.openConnectionTCP(modbusHost=PM_modbusHost, modbusPort=PM_modbusPort)
self.PM_getData_start = PM_startReg
self.PM_getData_count = PM_maxRegsRead
self.PM_cacheEnabled = PM_cacheEnabled
self.PM_base_commands = PM_base_commands
self.load_modbus_map()
valid_addresses = self.elaborate_validAddresses()
log.debug("valid_addresses: %s" % valid_addresses)
self.mb.load_valid_addresses(valid_addresses)
self.buffer_skip = []
self.data_default = []
def load_modbus_map(self):
filename = PATH_PM_SCHNEIDERELECTRICIEM3255
self.modbusmap = {}
i = 0
separator = ";"
with open(filename) as f:
for line in f:
line = line.rstrip()
line.replace("'", "")
if separator not in line:
continue
if line.startswith("#"):
continue
if line.startswith(separator):
continue
key, address, size, datatype = line.split(separator)
try:
self.modbusmap.setdefault(key, [])
self.modbusmap[key].append(int(address) + self.PM_addressoffset)
self.modbusmap[key].append(int(size))
self.modbusmap[key].append(datatype)
except ValueError:
pass
i += 1
text = "["
validaddresses = []
for k in self.modbusmap.keys():
if len(self.modbusmap[k]) == 3:
text += "'%s => %s,%s,%s', " % (k, self.modbusmap[k][0], self.modbusmap[k][1], self.modbusmap[k][2])
if self.modbusmap[k][0] not in validaddresses:
validaddresses.append(self.modbusmap[k][0])
else:
text += "**SKIP** item \"%s\"" % k
text += "]"
log.debug("Read %s modbus registers: %s" % (i, text))
def elaborate_validAddresses(self):
addresses = []
log.debug("modbusmap: %s" % self.modbusmap)
for k in self.modbusmap.keys():
address = self.modbusmap[k][0]
i = 0
size = self.modbusmap[k][1]
while i <= size:
address = address + i
if address not in addresses:
addresses.append(address)
i += 1
return sorted(addresses)
def _modbusRead(self, key):
if self.PM_cacheEnabled is False:
# W/O cache
val = self.mb.readRegistersAndDecode(self.modbusmap[key][0],self.modbusmap[key][1],self.modbusmap[key][2])
else:
# with cache
val = self.mb.cachedRead(self.modbusmap[key][0], self.modbusmap[key][1], self.modbusmap[key][2])
log.debug('"%s" Modbus: (%s,%s,%s) = %s' % (key, self.modbusmap[key][0],
self.modbusmap[key][1], self.modbusmap[key][2], val))
if self.modbusmap[key][2].startswith("float"):
try:
if math.isnan(val):
log.debug("NaN regs %s => 0" % self.modbusmap[key][0])
val = 0
except TypeError:
val = 0
return val
def readL1Active(self):
# *1000 kW => W
return self._modbusRead('L1Active')*1000
def readL2Active(self):
# *1000 kW => W
return self._modbusRead('L2Active')*1000
def readL3Active(self):
# *1000 kW => W
return self._modbusRead('L3Active')*1000
def readL1Current(self):
return self._modbusRead('L1Current')
def readL2Current(self):
return self._modbusRead('L2Current')
def readL3Current(self):
return self._modbusRead('L3Current')
def readL1Voltage(self):
return self._modbusRead('L1Voltage')
def readL2Voltage(self):
return self._modbusRead('L2Voltage')
def readL3Voltage(self):
return self._modbusRead('L3Voltage')
def readFreq(self):
return self._modbusRead('FREQ')
def readDinput(self):
Dinput = self._modbusRead('Digital Input Status')
def readL1Apparent(self, L1Voltage=None, L1Current=None):
if L1Voltage is None:
L1Voltage = self.readL1Voltage()
if L1Current is None:
L1Current = self.readL1Current()
return L1Voltage * L1Current
def readL2Apparent(self, L2Voltage=None, L2Current=None):
if L2Voltage is None:
L2Voltage = self.readL2Voltage()
if L2Current is None:
L2Current = self.readL2Current()
return L2Voltage * L2Current
def readL3Apparent(self, L3Voltage=None, L3Current=None):
if L3Voltage is None:
L3Voltage = self.readL3Voltage()
if L3Current is None:
L3Current = self.readL3Current()
return L3Voltage * L3Current
def readL1CosPhi(self, L1Voltage=None, L1C=None, L1AC=None):
if L1Voltage is None:
L1Voltage = self.readL1Voltage()
if L1C is None:
L1C = self.readL1Current()
if L1AC is None:
L1AC = self.readL1Active()
VI = L1Voltage * L1C
if VI == 0:
return 0
return L1AC / VI
def readL2CosPhi(self, L2Voltage=None, L2C=None, L2AC=None):
if L2Voltage is None:
L2Voltage = self.readL2Voltage()
if L2C is None:
L2C = self.readL2Current()
if L2AC is None:
L2AC = self.readL2Active()
VI = L2Voltage * L2C
if VI == 0:
return 0
return L2AC / VI
def readL3CosPhi(self, L3Voltage=None, L3C=None, L3AC=None):
if L3Voltage is None:
L3Voltage = self.readL3Voltage()
if L3C is None:
L3C = self.readL3Current()
if L3AC is None:
L3AC = self.readL3Active()
VI = L3Voltage * L3C
if VI == 0:
return 0
return L3AC / VI
def readL1Reactive(self):
V = float(self.readL1Voltage())
I = float(self.readL1Current())
return math.sqrt(math.pow((V*I), 2) - math.pow(self.readL1Active(), 2))
def readL2Reactive(self):
V = float(self.readL2Voltage())
I = float(self.readL2Current())
return math.sqrt(math.pow((V*I), 2) - math.pow(self.readL2Active(), 2))
def readL3Reactive(self):
V = float(self.readL3Voltage())
I = float(self.readL3Current())
return math.sqrt(math.pow((V*I), 2) - math.pow(self.readL3Active(), 2))
def readActiveEnergy(self):
return self._modbusRead('PartialActiveEnergy')
def readReactiveEnergy(self):
return self._modbusRead('PartialReactiveEnergy')
def readTotalPowerFactor(self):
return self._modbusRead('TotalPowerFactor')
def _capacitiveOrInductive(self):
tpf = self.readTotalPowerFactor()
if tpf < -1:
return "-C"
elif tpf >= -1 and tpf < 0:
return "-I"
elif tpf >= 0 and tpf < 1:
return "+I"
elif tpf >= 1:
return "+C"
def readInductiveEnergy(self):
return self.readReactiveEnergy()
def readCapacitiveEnergy(self):
return self.readReactiveEnergy()
def readTotalActivePW(self):
# *1000 kW => W
return self._modbusRead('TotalActivePW')*1000
def readTotalApparentPW(self):
# *1000 kVA => VA
return self._modbusRead('TotalApparentPW')*1000
def bysec_value(self, x, size=16):
val_shift = size/2
if size == 8:
val_mask = 0xf
else:
val_mask = 0xff
c = (x >> val_shift) & val_mask
f = x & val_mask
return c, f
def read_date_time(self):
date = None
year = 2000 + int(self._modbusRead("YYYY"))
month, tmp = self.bysec_value(self._modbusRead("MM-WW-GG"))
weekday, day = self.bysec_value(tmp, 8)
hours, minutes = self.bysec_value(self._modbusRead("HH-MM"))
seconds = int(self._modbusRead("MS")) / 1000
log.warn("read YYYY=%s MM=%s DD=%s HH=%s MM=%s SS=%s" % (year, month, day, hours, minutes, seconds))
date = datetime.datetime(year, month, day, hours, minutes, seconds)
log.warn("data: %s" % date)
return date
def _modbusWrite(self, command, base_address, value, mb_funcall, force=False):
log.debug('CMD: %s Modbus (FC=%s): %s = %s' % (command, mb_funcall, base_address, value))
skip_encode = True
val = self.mb.writeRegisters((base_address + self.PM_addressoffset), value, mb_funcall, force, skip_encode=skip_encode)
log.debug('Write done: %s' % val)
val = self.mb.readRegisters(address=(5375 + self.PM_addressoffset), count=2, mb_type='int16', mb_funcall=3, force=True)
log.debug("result: %s" % val)
if val[1] == 0:
log.warn("!!! Command SUCCESSFUL !!!")
elif val[1] == 3000:
log.warn("INVALID Command or COM.PROTECTION")
elif val[1] == 3001:
log.warn("INVALID Parameter")
elif val[1] == 3002:
log.warn("INVALID number of parameters")
elif val[1] == 3007:
log.warn("Operation Not Performed")
else:
log.warn('NOT valid value: "%s"' % val[1])
return val[1]
def encode_data(self, payload):
payload_processed = []
for i in payload:
try:
value = self.mb.encode_field(i[0], i[1])
for item in value:
payload_processed.append(item)
if len(value) > 1:
log.debug("multibyte %s => %s" % (i, value))
except Exception as e:
log.exception(e)
return payload_processed
def cmd_set_date_time(self, key='Set DateTime', data=datetime.datetime.today()):
log.debug('Start "cmd_set_date_time" routine: %s %s' % (PM_settings[key], data))
payload = [
[int(PM_settings[key]['command']), 'int16'],
[0, 'int16'],
[int(data.year), 'int16'],
[int(data.month), 'int16'],
[int(data.day), 'int16'],
[int(data.hour), 'int16'],
[int(data.minute), 'int16'],
[int(data.second), 'int16'],
[0, 'int16'],
]
payload_processed = self.encode_data(payload)
ret = self._modbusWrite(command=PM_settings[key],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
log.debug('End "cmd_set_date_time" routine: %s' % ret)
def cmd_set_wiring(self, key='Set Wiring'):
log.debug('Start "cmd_set_wiring" routine: %s' % PM_settings[key])
payload = [
[int(PM_settings[key]['command']), 'int16'],
[0, 'uint16'],
[0, 'uint16'],
[0, 'uint16'],
[int(PM_settings[key]['Power System Configuration']), 'uint16'],
[int(PM_settings[key]['Nominal Frequency']), 'uint16'],
[0, 'float32'],
[0, 'float32'],
[0, 'float32'],
[0, 'uint16'],
[0, 'uint16'],
[float(PM_settings[key]['VT Primary']), 'float32'],
[int(PM_settings[key]['VT Secondary']), 'uint16'],
[int(PM_settings[key]['Number of CTs']), 'uint16'],
[int(PM_settings[key]['CT Primary']), 'uint16'],
[int(PM_settings[key]['CT Secondary']), 'uint16'],
[0, 'uint16'],
[0, 'uint16'],
[0, 'uint16'],
[0, 'uint16'],
[int(PM_settings[key]['VT Connection type']), 'uint16']
]
payload_processed = self.encode_data(payload)
ret = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
log.debug('End "cmd_set_wiring" routine: %s' % ret)
def cmd_set_pulse_output(self, key='Set Pulse Output'):
log.debug('Start "cmd_set_pulse_output" routine: %s' % PM_settings[key])
payload = [
[int(PM_settings[key]['command']), 'int16'],
[0, 'uint16'],
[0, 'uint16'],
[int(PM_settings[key]['Pulse Output enable']), 'uint16'],
[float(PM_settings[key]['Pulse constant']), 'float32'],
[0, 'uint16'],
[0, 'uint16'],
[float(0), 'float32'],
[0, 'uint16'],
[0, 'uint16'],
[float(0), 'float32'],
]
payload_processed = self.encode_data(payload)
ret = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
payload = [
[int(PM_settings[key]['command2']), 'int16'],
[0, 'uint16'],
[0, 'uint16'],
[int(PM_settings[key]['Pulse width']), 'uint16'],
]
payload_processed = self.encode_data(payload)
ret2 = self._modbusWrite(command=PM_settings[key]['command2'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
log.debug('End "cmd_set_pulse_output" routine: %s %s' % (ret, ret2))
def cmd_set_tariff(self, key='Set Tariff'):
log.debug('Start "cmd_set_tariff" routine: %s' % PM_settings[key])
payload = [
[int(PM_settings[key]['command']), 'int16'],
[0, 'uint16'],
[int(PM_settings[key]['Multi Tariff Mode']), 'uint16']
]
payload_processed = self.encode_data(payload)
ret = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
payload = [
[int(PM_settings[key]['command2']), 'int16'],
[0, 'uint16'],
[int(PM_settings[key]['Tariff']), 'uint16']
]
payload_processed = self.encode_data(payload)
ret2 = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
log.debug('End "cmd_set_tariff" routine: %s %s' % (ret, ret2))
def cmd_set_digital_input_as_partial_energy_reset(self, key='Set Digital Input as Partial Energy Reset'):
log.debug('Start "cmd_set_digital_input_as_partial_energy_reset" routine: %s' % PM_settings[key])
payload = [
[int(PM_settings[key]['command']), 'int16'],
[0, 'uint16'],
[int(PM_settings[key]['Digital Input to Associate']), 'uint16']
]
payload_processed = self.encode_data(payload)
ret = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
log.debug('End "cmd_set_digital_input_as_partial_energy_reset" routine: %s' % ret)
def cmd_input_metering_setup(self, key='Input Metering Setup'):
log.debug('Start "cmd_input_metering_setup" routine: %s' % PM_settings[key])
payload = [
[int(PM_settings[key]['command']), 'int16'],
[0, 'uint16'],
[int(PM_settings[key]['Input Metering Channel']), 'uint16'],
[PM_settings[key]['Label'], 'str'],
[float(PM_settings[key]['Pulse Weight']), 'float32'],
[0, 'uint16'],
[int(PM_settings[key]['Digital Input Association']), 'uint16']
]
payload_processed = self.encode_data(payload)
ret = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
log.debug('End "cmd_input_metering_setup" routine: %s' % ret)
def cmd_overload_alarm_setup(self, key='Overload Alarm Setup'):
log.debug('Start "cmd_overload_alarm_setup" routine: %s' % PM_settings[key])
payload = [
[int(PM_settings[key]['command']), 'int16'],
[0, 'uint16'],
[int(PM_settings[key]['Alarm ID']), 'uint16'],
[0, 'uint16'],
[0, 'uint16'],
[0, 'uint16'],
[int(PM_settings[key]['Enabled']), 'uint16'],
[float(PM_settings[key]['Pickup value']), 'float32'],
[0, 'uint32'],
[0, 'float32'],
[0, 'uint32'],
[0, 'uint16'],
[0, 'uint16'],
[0, 'uint16'],
[0, 'uint16']
]
payload_processed = self.encode_data(payload)
ret = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
payload = [
[int(PM_settings[key]['command2']), 'int16'],
[0, 'uint16'],
[0, 'float32'],
[0, 'uint32'],
[int(PM_settings[key]['Digital Output to Associate']), 'bitmap']
]
payload_processed = self.encode_data(payload)
ret2 = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
payload = [
[int(PM_settings[key]['command2']), 'int16'],
[0, 'uint16']
]
payload_processed = self.encode_data(payload)
ret3 = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
log.debug('End "cmd_overload_alarm_setup" routine: %s %s %s' % (ret, ret2, ret3))
def cmd_communications_setup(self, key='Communications Setup'):
log.debug('Start "cmd_communications_setup" routine: %s' % PM_settings[key])
payload = [
[int(PM_settings[key]['command']), 'int16'],
[0, 'uint16'],
[0, 'uint16'],
[0, 'uint16'],
[int(PM_settings[key]['Address']), 'uint16'],
[int(PM_settings[key]['Baud Rate']), 'uint16'],
[int(PM_settings[key]['Parity']), 'uint16'],
[0, 'uint16']
]
payload_processed = self.encode_data(payload)
ret = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
log.debug('End "cmd_communications_setup" routine: %s' % ret)
def cmd_reset_partial_energy_counters(self, key='Reset Partial Energy Counters'):
log.debug('Start "cmd_reset_partial_energy_counters" routine: %s' % PM_settings[key])
payload = [
[int(PM_settings[key]['command']), 'int16']
]
payload_processed = self.encode_data(payload)
ret = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
log.debug('End "cmd_reset_partial_energy_counters" routine: %s' % ret)
def cmd_reset_input_metering_counter(self, key='Reset Input Metering Counter'):
log.debug('Start "cmd_reset_input_metering_counter" routine: %s' % PM_settings[key])
payload = [
[int(PM_settings[key]['command']), 'int16']
]
payload_processed = self.encode_data(payload)
ret = self._modbusWrite(command=PM_settings[key]['command'],base_address=self.PM_base_commands, value=payload_processed, mb_funcall=16, force=True)
log.debug('End "cmd_reset_input_metering_counter" routine: %s' % ret)