Make RosFluidPressure: Missing Connector for pressure and variance #138
Comments
Solved by modifiing UPROPERTY(EditAnywhere) -> UPROPERTY(EditAnywhere, BlueprintReadWrite) |
Hello, it is same issue as this BP does not support double |
Oh, interesting. Thanks for letting us know. |
No Problem :) |
I created PR |
The Connector to set the Pressure is missing in the Blueprint Node.
Is there an option i missed out or is this an bug?
I'm using UE 5.3.2 and tired the devel and UE 5.3 branch of this repo. ROS2 version is Humble.
For the IMU Message the node has all its connectors.
Thanks!
The text was updated successfully, but these errors were encountered: