Notifications
You must be signed in to change notification settings - Fork 4
/
Copy pathbed_mesh.cfg
178 lines (158 loc) · 6.68 KB
/
bed_mesh.cfg
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
#####################################################################
# Bed Mesh Definition
#####################################################################
[bed_mesh]
speed: 100
horizontal_move_z: 20
mesh_min: 15,15
mesh_max: 105,105
algorithm: lagrange
## relative_reference_index should be the location where the
## For the center of the bed: [(7x7)-1] / 2 = position 24
probe_count: 3,3
relative_reference_index: 4
#fade_start: 1
#fade_end: 10
#fade_target: 0
move_check_distance: 3
split_delta_z: 0.0125
mesh_pps: 2,2
#bicubic_tension: 0.2
#####################################################################
# Macros
#####################################################################
[gcode_macro BED_MESH_CALIBRATE]
rename_existing: _BED_MESH_CALIBRATE
description: Perform Mesh Bed Leveling with klicky automount
variable_parameter_AREA_START : 0,0
variable_parameter_AREA_END : 0,0
; the clearance between print area and probe area
variable_mesh_area_offset : 5.0
; number of sample per probe point
variable_probe_samples : 2
; minimum probe count
variable_min_probe_count : 3
; scale up the probe count, should be 1.0 ~ < variable_max_probe_count/variable_min_probe_count
variable_probe_count_scale_factor : 1.0
gcode:
{% set V = printer["gcode_macro _User_Variables"].verbose %}
{% if V %}
{ action_respond_info("Bed Mesh Calibrate") }
{% endif %}
BED_MESH_CLEAR
SMARTHOME
_CheckProbe action=query
G90
Attach_Probe_Lock
SMARTQGL
{% if params.AREA_START and params.AREA_END %}
{% set bedMeshConfig = printer["configfile"].config["bed_mesh"] %}
{% set safe_min_x = bedMeshConfig.mesh_min.split(",")[0]|float %}
{% set safe_min_y = bedMeshConfig.mesh_min.split(",")[1]|float %}
{% set safe_max_x = bedMeshConfig.mesh_max.split(",")[0]|float %}
{% set safe_max_y = bedMeshConfig.mesh_max.split(",")[1]|float %}
{% set area_min_x = params.AREA_START.split(",")[0]|float %}
{% set area_min_y = params.AREA_START.split(",")[1]|float %}
{% set area_max_x = params.AREA_END.split(",")[0]|float %}
{% set area_max_y = params.AREA_END.split(",")[1]|float %}
{% if bedMeshConfig.probe_count.split(",")|length == 2 %}
{% set meshPointX = bedMeshConfig.probe_count.split(",")[0]|int %}
{% set meshPointY = bedMeshConfig.probe_count.split(",")[1]|int %}
{% else %}
{% set meshPointX = bedMeshConfig.probe_count.split(",")[0]|int %}
{% set meshPointY = bedMeshConfig.probe_count.split(",")[0]|int %}
{% endif %}
{% set meshMaxPointX = meshPointX %}
{% set meshMaxPointY = meshPointY %}
{% if (area_min_x < area_max_x) and (area_min_y < area_max_y) %}
{% if area_min_x - mesh_area_offset >= safe_min_x %}
{% set area_min_x = area_min_x - mesh_area_offset %}
{% else %}
{% set area_min_x = safe_min_x %}
{% endif %}
{% if area_min_y - mesh_area_offset >= safe_min_y %}
{% set area_min_y = area_min_y - mesh_area_offset %}
{% else %}
{% set area_min_y = safe_min_y %}
{% endif %}
{% if area_max_x + mesh_area_offset <= safe_max_x %}
{% set area_max_x = area_max_x + mesh_area_offset %}
{% else %}
{% set area_max_x = safe_max_x %}
{% endif %}
{% if area_max_y + mesh_area_offset <= safe_max_y %}
{% set area_max_y = area_max_y + mesh_area_offset %}
{% else %}
{% set area_max_y = safe_max_y %}
{% endif %}
{% set meshPointX = (meshPointX * (area_max_x - area_min_x) / (safe_max_x - safe_min_x) * probe_count_scale_factor)|round(0)|int %}
{% if meshPointX < min_probe_count %}
{% set meshPointX = min_probe_count %}
{% endif %}
{% if meshPointX > meshMaxPointX %}
{% set meshPointX = meshMaxPointX %}
{% endif %}
{% set meshPointY = (meshPointY * (area_max_y -area_min_y ) / (safe_max_y - safe_min_y) * probe_count_scale_factor )|round(0)|int %}
{% if meshPointY < min_probe_count %}
{% set meshPointY = min_probe_count %}
{% endif %}
{% if meshPointY > meshMaxPointY %}
{% set meshPointY = meshMaxPointY %}
{% endif %}
_BED_MESH_CALIBRATE mesh_min={area_min_x},{area_min_y} mesh_max={area_max_x},{area_max_y} probe_count={meshPointX},{meshPointY} samples={probe_samples|int}
{% else %}
_BED_MESH_CALIBRATE
{% endif %}
{% else %}
_BED_MESH_CALIBRATE
{% endif %}
Dock_Probe_Unlock
## use MESH_STORE -> generate MESH and save immediately
## use MESH_STORE SAVE=false -> generate MESH and save it later
[gcode_macro MESH_STORE]
variable_save_at_end: 'false'
gcode:
# set default parameter value
{% set save = params.SAVE|default('true') %}
BED_MESH_CALIBRATE
BED_MESH_PROFILE SAVE=Voron-Bed_Temp-{printer.heater_bed.target|int}C
BED_MESH_PROFILE REMOVE=default
# Move to Middle
G90 ; set absolute
G0 Z7.5 F900 ; lift nozzle
G0 X175 Y175 Z30 F7200 ; move to middle
{% if save|lower == 'true' %}
_PRINT_AR T="MESH: Save Config!"
SAVE_CONFIG
{% else %}
_PRINT_AR T="MESH: Save Config after print done"
SET_GCODE_VARIABLE MACRO=MESH_STORE VARIABLE=save_at_end VALUE='"true"'
{% endif %}
## use MESH_LOAD -> load an existing MESH
## use MESH_LOAD AUTO=true -> load an existing MESH or generate a new one and prepare it to be saved after print end
[gcode_macro MESH_LOAD]
# set that to true to enable autogeneration of a missing mesh
gcode:
# set default parameter value
{% set auto = params.AUTO|default('false') %}
{% set bed_temp = printer.heater_bed.target|int %}
{% if printer.configfile.config["bed_mesh Voron-Bed_Temp-" + bed_temp|string + "C"] is defined %}
BED_MESH_CLEAR
BED_MESH_PROFILE LOAD=Voron-Bed_Temp-{printer.heater_bed.target|int}C
_PRINT_AR T="{"MESH: Voron-Bed_Temp-" + bed_temp|string + "C loaded"}"
{% else %}
{% if auto|lower == 'true' %}
_PRINT_AR T="{"MESH: Voron-Bed_Temp-" + bed_temp|string + "C needs to be generated"}"
MESH_STORE SAVE=false
{% else %}
_PRINT_AR T="{"MESH ERROR: Voron-Bed_Temp-" + bed_temp|string + "C not defined"}"
{% endif %}
{% endif %}
## add this to your PRINT_END to save a mesh if needed 10 seconds after print ended
## UPDATE_DELAYED_GCODE ID=_MESH_SAVE DURATION=10
[delayed_gcode _MESH_SAVE]
gcode:
{% if printer["gcode_macro MESH_STORE"].save_at_end == 'true' %}
_PRINT_AR T="MESH: Save Config!"
SAVE_CONFIG
{% endif %}