Skip to content

Commit

Permalink
Add support for YTL DEM4A meter
Browse files Browse the repository at this point in the history
  • Loading branch information
borg42 committed Nov 10, 2023
1 parent 9e2f400 commit 37fba4d
Show file tree
Hide file tree
Showing 2 changed files with 54 additions and 14 deletions.
53 changes: 45 additions & 8 deletions warp/meter.c
Original file line number Diff line number Diff line change
Expand Up @@ -42,6 +42,9 @@ static const MeterDefinition meter_sdm72v2[] = {
static const MeterDefinition meter_dsz15dzmod[] = {
#include "meter_dsz15dzmod_def.inc"
};
static const MeterDefinition meter_dem4a[] = {
#include "meter_dem4a_def.inc"
};

static void modbus_store_tx_frame_data_bytes(const uint8_t *data, const uint16_t length) {
for(uint16_t i = 0; i < length; i++) {
Expand Down Expand Up @@ -225,6 +228,7 @@ void meter_set_meter_type(MeterType type) {
case METER_TYPE_SDM630: meter.slave_address = 0x01; meter.current_meter = &meter_sdm630[0]; break;
case METER_TYPE_SDM630MCTV2: meter.slave_address = 0x01; meter.current_meter = &meter_sdm630[0]; break;
case METER_TYPE_DSZ15DZMOD: meter.slave_address = 0x37; meter.current_meter = &meter_dsz15dzmod[0]; break;
case METER_TYPE_DEM4A: meter.slave_address = 0x01; meter.current_meter = &meter_dem4a[0]; break;
default: meter.slave_address = 0; meter.current_meter = NULL; break;
}

Expand All @@ -237,13 +241,39 @@ void meter_find_meter_type(void) {

switch(find_meter_state) {
case 0: {
// Read meter code for YTL meters register with slave address 1 (SDM)
meter_read_registers(MODBUS_FC_READ_HOLDING_REGISTERS, 1, 0x100D, 1);
find_meter_state++;
break;
}

case 1: {
uint16_t meter_code = 0xFFFF;
bool ret = meter_get_read_registers_response(MODBUS_FC_READ_HOLDING_REGISTERS, &meter_code, 1);
if(ret) {
if(meter_code != 0xFFFF) {
rs485.modbus_common_error_counters.timeout = 0;
}

modbus_clear_request(&rs485);
switch(meter_code) {
case 0x0006: meter_set_meter_type(METER_TYPE_DEM4A); find_meter_state = 0; rs485.modbus_common_error_counters.timeout = 0; return;
default: meter.type = METER_TYPE_UNKNOWN; break;
}

find_meter_state++;
}
break;
}

case 2: {
// Read meter code register with slave address 1 (SDM)
meter_read_registers(MODBUS_FC_READ_HOLDING_REGISTERS, 1, METER_SDM_HOLDING_REG_METER_CODE, 1);
find_meter_state++;
break;
}

case 1: {
case 3: {
uint16_t meter_code = 0xFFFF;
bool ret = meter_get_read_registers_response(MODBUS_FC_READ_HOLDING_REGISTERS, &meter_code, 1);
if(ret) {
Expand All @@ -266,14 +296,15 @@ void meter_find_meter_type(void) {
break;
}

case 2: {

case 4: {
// Read meter code register with slave address 0x37 (Eltako)
meter_read_registers(MODBUS_FC_READ_HOLDING_REGISTERS, 0x37, METER_SDM_HOLDING_REG_METER_CODE, 2);
find_meter_state++;
break;
}

case 3: {
case 5: {
uint32_t meter_code = 0xFFFFFFFF;
bool ret = meter_get_read_registers_response(MODBUS_FC_READ_HOLDING_REGISTERS, &meter_code, 2);
if(ret) {
Expand Down Expand Up @@ -304,6 +335,8 @@ void meter_handle_new_data(MeterRegisterType data, const MeterDefinition *defini
definition->register_set_address->f = data.f * definition->scale_factor;
} else if(definition->register_data_type == METER_REGISTER_DATA_TYPE_INT32) {
definition->register_set_address->f = ((float)data.i32) * definition->scale_factor;
} else if(definition->register_data_type == METER_REGISTER_DATA_TYPE_INT16) {
definition->register_set_address->f = ((float)data.i16) * definition->scale_factor;
} else {
loge("Unsupported data type: %d\n\r", definition->register_data_type);
}
Expand Down Expand Up @@ -359,6 +392,10 @@ void meter_handle_register_set_read_done(void) {
}
}

uint8_t meter_get_register_size(uint16_t position) {
return meter.current_meter[position].register_data_type >= METER_REGISTER_DATA_TYPE_INT16 ? 1: 2;
}

void meter_tick(void) {
static uint8_t last_state = 255;
static bool read_fast = false;
Expand Down Expand Up @@ -403,10 +440,10 @@ void meter_tick(void) {
switch(meter.state) {
case 0: { // request
if(system_timer_is_time_elapsed_ms(meter.register_fast_time, 500) || read_fast) {
meter_read_registers(MODBUS_FC_READ_INPUT_REGISTERS, meter.slave_address, meter.current_meter[meter.register_fast_position].register_address, 2);
meter_read_registers(MODBUS_FC_READ_INPUT_REGISTERS, meter.slave_address, meter.current_meter[meter.register_fast_position].register_address, meter_get_register_size(meter.register_fast_position));
read_fast = true;
} else {
meter_read_registers(MODBUS_FC_READ_INPUT_REGISTERS, meter.slave_address, meter.current_meter[meter.register_full_position].register_address, 2);
meter_read_registers(MODBUS_FC_READ_INPUT_REGISTERS, meter.slave_address, meter.current_meter[meter.register_full_position].register_address, meter_get_register_size(meter.register_full_position));
read_fast = false;
}
meter.state++;
Expand All @@ -416,7 +453,7 @@ void meter_tick(void) {
case 1: { // read
bool ret = false;
MeterRegisterType data;
ret = meter_get_read_registers_response(MODBUS_FC_READ_INPUT_REGISTERS, &data, 2);
ret = meter_get_read_registers_response(MODBUS_FC_READ_INPUT_REGISTERS, &data, meter_get_register_size(read_fast ? meter.register_fast_position : meter.register_full_position));
if(ret) {
meter_handle_new_data(data, read_fast ? &meter.current_meter[meter.register_fast_position] : &meter.current_meter[meter.register_full_position]);
modbus_clear_request(&rs485);
Expand Down Expand Up @@ -455,8 +492,8 @@ void meter_tick(void) {
break;
}

// Eltako meter does not have system type configuration
if(meter.type == METER_TYPE_DSZ15DZMOD) {
// Eltako and YTL meter do not have system type configuration
if((meter.type == METER_TYPE_DSZ15DZMOD) || (meter.type == METER_TYPE_DEM4A)) {
// For SDM meters this is done during system type check
meter_handle_phases_connected();
meter.state = 0;
Expand Down
15 changes: 9 additions & 6 deletions warp/meter.h
Original file line number Diff line number Diff line change
Expand Up @@ -49,22 +49,25 @@
typedef enum {
METER_TYPE_UNKNOWN = 0,
METER_TYPE_UNSUPPORTED = 1,
METER_TYPE_SDM630 = 2,
METER_TYPE_SDM72V2 = 3,
METER_TYPE_SDM72CTM = 4,
METER_TYPE_SDM630MCTV2 = 5,
METER_TYPE_DSZ15DZMOD = 6 // Eltako
METER_TYPE_SDM630 = 2, // Eastron
METER_TYPE_SDM72V2 = 3, // Eastron
METER_TYPE_SDM72CTM = 4, // Eastron
METER_TYPE_SDM630MCTV2 = 5, // Eastron
METER_TYPE_DSZ15DZMOD = 6, // Eltako
METER_TYPE_DEM4A = 7 // YTL
} MeterType;

typedef enum {
METER_REGISTER_DATA_TYPE_FLOAT = 0,
METER_REGISTER_DATA_TYPE_INT32 = 1
METER_REGISTER_DATA_TYPE_INT32 = 1,
METER_REGISTER_DATA_TYPE_INT16 = 2
} MeterRegisterDataType;

typedef union {
float f;
uint32_t data;
int32_t i32;
int16_t i16;
uint16_t u16[2];
} MeterRegisterType;

Expand Down

0 comments on commit 37fba4d