Skip to content

Commit

Permalink
WIP
Browse files Browse the repository at this point in the history
  • Loading branch information
Xavier Berger committed Oct 30, 2024
1 parent dd9eda9 commit f616680
Showing 1 changed file with 257 additions and 0 deletions.
257 changes: 257 additions & 0 deletions solar_router/power_meter_JSY_modbus.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,257 @@
# Protocole du JSK
uart:
id: mod_bus
tx_pin: 17
rx_pin: 16
baud_rate: 38400
stop_bits: 1
# debug:
# direction: BOTH
# dummy_receiver: false
# after:
# timeout: 150ms
# sequence:
# - lambda: |-
# UARTDebug::log_string(direction, bytes);

modbus:
#flow_control_pin: 5
#send_wait_time: 200ms
id: modbus1

modbus_controller:
- id: jsymk
## the Modbus device addr
address: 0x1
modbus_id: modbus1
update_interval: 0.75s
command_throttle: 50ms

sensor:
# tension de l'alimentation
- platform: modbus_controller
modbus_controller_id: jsymk
id: Tension
#name: "${friendly_name} Tension JSYMK"
address: 0x0048
unit_of_measurement: "V"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Intensité traversant le tore
- platform: modbus_controller
modbus_controller_id: jsymk
id: Itore
name: "${friendly_name} I_ECS JSYMK"
address: 0x0049
unit_of_measurement: "A"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Puissance traversant le tore
- platform: modbus_controller
modbus_controller_id: jsymk
id: puecs
name: "${friendly_name} P_ECS JSYMK"
address: 0x004A
unit_of_measurement: "W"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Energie lue dans le tore
- platform: modbus_controller
modbus_controller_id: jsymk
id: energietore
name: "${friendly_name} Energie ECS JSYMK"
address: 0x004B
unit_of_measurement: "kWh"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# FP lue dans le tore
- platform: modbus_controller
modbus_controller_id: jsymk
id: fptore
#name: "${friendly_name} FP Tore JSYMK"
address: 0x004C
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Energie NEG lue dans le tore
- platform: modbus_controller
modbus_controller_id: jsymk
id: energietoren
name: "${friendly_name} Energie ECS Neg JSYMK"
address: 0x004D
unit_of_measurement: "kWh"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4
# Sens du courant dans la pince
- platform: modbus_controller
modbus_controller_id: jsymk
id: senspince
#name: "${friendly_name} Sens_Pince JSYMK"
address: 0x004E
register_type: holding
value_type: U_DWORD
bitmask: 0X00010000
filters:
- multiply: 1
register_count: 1
response_size: 4
# Sens du courant dans le tore
- platform: modbus_controller
modbus_controller_id: jsymk
id: senstor
#name: "${friendly_name} Sens_Tore JSYMK"
address: 0x004E
register_type: holding
value_type: U_DWORD
accuracy_decimals: 0
bitmask: 0X01000000
filters:
- multiply: 1
register_count: 1
response_size: 4

# Fréquence de l'alimentation
- platform: modbus_controller
modbus_controller_id: jsymk
id: frequence
#name: "${friendly_name} Frequence JSYMK"
address: 0x004F
unit_of_measurement: "hz"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.01
register_count: 1
response_size: 4

# tension de l'alimentation
- platform: modbus_controller
modbus_controller_id: jsymk
id: Tension2
#name: "${friendly_name} U_Reseau JSYMK"
address: 0x0050
unit_of_measurement: "V"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Intensité lue dans la pince
- platform: modbus_controller
modbus_controller_id: jsymk
id: Ireseau
#name: "${friendly_name} I_Reseau JSYMK"
address: 0x0051
unit_of_measurement: "A"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# puissance lue dans la pince
- platform: modbus_controller
modbus_controller_id: jsymk
id: pureseau
#name: "${friendly_name} P_Reseau JSYMK"
address: 0x0052
unit_of_measurement: "W"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4
on_value:
then:
- lambda: |-
if ( id(senspince).state == 1 ) {
id(pureseau1).publish_state( id(pureseau).state *-1);
} else {
id(pureseau1).publish_state( id(pureseau).state );
}
# Energie lue dans la pince
- platform: modbus_controller
modbus_controller_id: jsymk
id: energiepince
#name: "${friendly_name} Energie Reseau JSYMK"
address: 0x0053
unit_of_measurement: "kWh"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Energie lue dans le tore
- platform: modbus_controller
modbus_controller_id: jsymk
id: fppince
#name: "${friendly_name} FP Pince JSYMK"
address: 0x0054
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

# Energie NEG lue dans le tore
- platform: modbus_controller
modbus_controller_id: jsymk
id: energienegpince
#name: "${friendly_name} Energie ECS Neg JSYMK"
address: 0x0055
unit_of_measurement: "kWh"
register_type: holding
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.0001
register_count: 1
response_size: 4

0 comments on commit f616680