46 changes: 44 additions & 2 deletions ontology/yaml/resources/HVAC/entity_types/ABSTRACT.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -1617,7 +1617,11 @@ MMCWDPC:
guid: "71874ee4-5596-4e90-ad14-8716a6b6de3a"
description: "Minimum water differential pressure control for mechanical cooling in a hydronic system."
is_abstract: true
opt_uses:
- bypass_valve_percentage_sensor
- failed_bypass_valve_alarm
uses:
- bypass_valve_percentage_command
- low_limit_mechanical_cooling_differential_pressure_sensor
- low_limit_mechanical_cooling_differential_pressure_setpoint
implements:
Expand Down Expand Up @@ -1645,6 +1649,8 @@ WDPC2X:
opt_uses:
- pressurization_request_count
- run_command
- high_differential_pressure_alarm
- low_differential_pressure_alarm
uses:
- differential_pressure_sensor_1
- differential_pressure_sensor_2
Expand Down Expand Up @@ -2457,6 +2463,7 @@ CHWRC:
opt_uses:
- chilled_water_flowrate_sensor
- chilled_water_valve_percentage_sensor
- cooling_request_count
- cooling_thermal_power_capacity
- discharge_air_temperature_sensor
- leaving_cooling_coil_temperature_sensor
Expand Down Expand Up @@ -4434,7 +4441,6 @@ HXRWISOVPM:
implements:
- MONITORING


HXSWISOVM:
guid: "3a617a80-2ab5-4eb5-9cf5-c327359a03c6"
description: "Heat exchanger supply isolation water valve control."
Expand All @@ -4445,7 +4451,6 @@ HXSWISOVM:
implements:
- MONITORING


HXRWISOVM:
guid: "48cee686-e728-4996-be87-0a280ecf9733"
description: "Heat exchanger return isolation water valve control."
Expand All @@ -4456,6 +4461,18 @@ HXRWISOVM:
implements:
- MONITORING

HXCRWISOVPM:
guid: "7fd2b89b-013d-4bad-833c-2b307a63cda5"
description: "Heat exchanger condensing return water isolation valve percentage control."
is_abstract: true
opt_uses:
- failed_heat_exchange_condensing_return_water_isolation_valve_alarm
uses:
- heat_exchange_condensing_return_water_isolation_valve_percentage_command
- heat_exchange_condensing_return_water_isolation_valve_percentage_sensor
implements:
- MONITORING

PWECVC:
guid: "c7d64d95-0215-4c9a-b422-a4fb7004f3e3"
description: "Process water electricconductivity drain valve control."
Expand All @@ -4476,6 +4493,30 @@ PWISOVM:
implements:
- MONITORING

PSWISOVPM:
guid: "e30d558a-61c5-4b9f-8511-9fc460117f7a"
description: "Process supply water iso valve control."
is_abstract: true
opt_uses:
- failed_process_supply_water_isolation_valve_alarm
uses:
- process_supply_water_isolation_valve_percentage_command
- process_supply_water_isolation_valve_percentage_sensor
implements:
- MONITORING

PRWISOVPM:
guid: "c87142d1-ffef-45ea-ab22-6e81b8393de4"
description: "Process return water iso valve control."
is_abstract: true
opt_uses:
- failed_process_return_water_isolation_valve_alarm
uses:
- process_return_water_isolation_valve_percentage_command
- process_return_water_isolation_valve_percentage_sensor
implements:
- MONITORING

PWVPM:
guid: "2335c3b8-b27f-4ef0-b15b-7df5e8d25e4a"
description: "Process water valve percentage control."
Expand Down Expand Up @@ -7526,6 +7567,7 @@ DAIDC:
- MONITORING
opt_uses:
- failed_discharge_air_isolation_damper_alarm
- discharge_air_isolation_damper_percentage_sensor


RAIDC4X:
Expand Down
13 changes: 12 additions & 1 deletion ontology/yaml/resources/HVAC/entity_types/CDWS.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -245,7 +245,7 @@ CDWS_SWTC_WSEBYPVPM:

CDWS_SWTC_WDPC_CLPM_WFRM_MWFRM:
guid: "35a284ef-332d-4e2f-b3f2-4eb94ce3d274"
description: "Chilled water system with supply temperature control, differential pressure control, and thermal load, flowrate and makeup water flowrate monitoring."
description: "Condensing water system with supply temperature control, differential pressure control, and thermal load, flowrate and makeup water flowrate monitoring."
is_canonical: true
implements:
- CDWS
Expand All @@ -255,6 +255,17 @@ CDWS_SWTC_WDPC_CLPM_WFRM_MWFRM:
- WFRM
- MWFRM

CDWS_SWTC_WFRM_MWFRM_BWFRM:
guid: "30b52a03-a020-4d65-8c57-bb9cb43e8b15"
description: "Condensing water system with flowrate control, blowdown and makeup water flowrate control."
is_canonical: true
implements:
- CDWS
- SWTC
- WFRM
- MWFRM
- BWFRM

###################################
### Existing Non-standard Types ###
###################################
Expand Down
51 changes: 51 additions & 0 deletions ontology/yaml/resources/HVAC/entity_types/CH.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -1031,6 +1031,57 @@ CH_SS_SWTC_DX2SWC_WDPM_RWISOVM_REFSM_REFPM:
- REFSM
- REFPM

CH_SS_SCHWTC_CHWDPC_CHWSWISOVPM_CWDT_CWDPM_CWRISOVPM_HXCRWISOVPM_CLPM:
guid: "c51bcdbe-1899-4e9e-9722-0b786b4dcdaf"
description: "Water cooled chiller with isolation on chilled and condensing water side, condensing water heat exchange isolation and cooling thermal power monitoring."
is_canonical: true
implements:
- CH
- SS
- SCHWTC
- CHWDPC
- CHWSWISOVPM
- CWDT
- CWDPM
- CWRISOVPM
- HXCRWISOVPM
- CLPM

CH_SS_SCHWTC_CHWDPC_CWDT_CWDPM_CHWSWISOVPM_CHWRWISOVPM_PSWISOVPM_PRWISOVPM_CWRISOVPM_HXCRWISOVPM_CLPM:
guid: "75203ebf-976f-4fef-84a1-7dec7f47c8a5"
description: "Water cooled chiller supplying water for chilled and process water systems, with isolation on chilled, process and condensing water side, condensing water heat exchange isolation and cooling thermal power monitoring."
is_canonical: true
implements:
- CH
- SS
- SCHWTC
- CHWDPC
- CWDT
- CWDPM
- CHWSWISOVPM
- CHWRWISOVPM
- PSWISOVPM
- PRWISOVPM
- CWRISOVPM
- HXCRWISOVPM
- CLPM


CH_SS_PSWTC_PWDPC_CWDT_CWDPM_PSWISOVPM_CWRISOVPM_CLPM:
guid: "8defc678-ce17-427c-8800-5a0bbe953bd4"
description: "Water cooled process chiller with isolation on condensing and process sides, and cooling thermal power monitoring."
is_canonical: true
implements:
- CH
- SS
- PSWTC
- PWDPC
- CWDT
- CWDPM
- PSWISOVPM
- CWRISOVPM
- CLPM

###################################
### Existing Non-standard Types ###
###################################
Expand Down
34 changes: 34 additions & 0 deletions ontology/yaml/resources/HVAC/entity_types/CHWS.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -111,6 +111,29 @@ CHWS_SWTC_WDPC_MMCWDPC_BYPVPM_WFRM:
- BYPVPM
- WFRM

CHWS_SWTC_WDPC_MMCWDPC_WFRM:
guid: "3141b35a-b4ae-4937-8f23-26ca97054a0d"
description: "Chilled water system with supply temperature control, differential pressure and min mechanical cooling differential pressure control and flow monitoring."
is_canonical: true
implements:
- CHWS
- SWTC
- WDPC
- MMCWDPC
- WFRM

CHWS_SWTC_WDPC2X_MMCWDPC_WSEBYPVPM_WFRM:
guid: "2f840d9d-461f-4a74-a660-c9a88b13bb5a"
description: "Chilled water system with supply temperature control, differential pressure and min mechanical cooling differential pressure control, waterside economizing, and flow monitoring."
is_canonical: true
implements:
- CHWS
- SWTC
- WDPC2X
- MMCWDPC
- WSEBYPVPM
- WFRM

CHWS_SWTC_WDPC2X_BYPVPM_WFRM:
guid: "e83ac652-c8c1-4e66-bfa6-5ad734aa9902"
description: "Chilled water system with dual differential pressure control, a bypass valve, and flowrate monitoring."
Expand Down Expand Up @@ -629,6 +652,17 @@ CHWS_SESWTC_SEWDPC_SEWFRM_WSEBYPVM:
- SEWFRM
- WSEBYPVM

CHWS_SWTC_WDPC2X_WSEBYPVPM_WFRM:
guid: "85ca9a77-bf43-4247-a7e2-b1f25f5fb563"
description: "Chilled water system with dual differential pressure control, waterside economizer bypass, flowrate monitoring."
is_canonical: true
implements:
- CHWS
- SWTC
- WDPC2X
- WSEBYPVPM
- WFRM

###################################
### Existing Non-standard Types ###
###################################
Expand Down
87 changes: 87 additions & 0 deletions ontology/yaml/resources/HVAC/entity_types/FCU.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -1771,6 +1771,93 @@ FCU_DFVSC_RTM_CO2C_HWZTC_CHWZTC_ZHM:
- CHWZTC
- ZHM

FCU_DSP_DFSS_DFVSMC_HTRC_RMM:
guid: "73330804-8365-4169-b5ae-0965b0c0b0dc"
description: "Fan coil unit with zone temperature and return air temperature control and electric heater."
is_canonical: true
implements:
- FCU
- DSP
- DFSS
- DFVSMC
- HTRC
- RMM

FCU_DSP_DFSS_DFVSMC_HTZC_MTC_RMM:
guid: "7c88378f-6a35-41d1-84d7-dfc064160120"
description: "Fan coil unit with zone temperature and mixed air temperature control and electric heater."
is_canonical: true
implements:
- FCU
- DSP
- DFSS
- DFVSMC
- HTZC
- MTC
- RMM

FCU_DSP_DFSS_DFVSMC_HTRC_RMM_DAIDC:
guid: "f7376d4d-d476-4e39-8fc8-732ba9f91d38"
description: "Fan coil unit with zone temperature and return air temperature control and electric heater and isolation damper."
is_canonical: true
implements:
- FCU
- DSP
- DFSS
- DFVSMC
- HTRC
- RMM
- DAIDC

FCU_DSP_DFSS_DFVSMC_HTRC_RMM_DAIDPC:
guid: "b8e47243-0626-461f-ae68-e690baa3d606"
description: "Fan coil unit with zone temperature and return air temperature control and electric heater and isolation damper."
is_canonical: true
implements:
- FCU
- DSP
- DFSS
- DFVSMC
- HTRC
- RMM
- DAIDPC

FCU_DFSS_DFVSC_CHWRC_RHC:
guid: "a3c64f5f-487f-4c52-b785-2e4ef329443f"
description: "Fan coil unit withreturn air humidity control and chilled water return air temperature control."
is_canonical: true
implements:
- FCU
- DFSS
- DFVSC
- CHWRC
- RHC

FCU_CSP_DFSS_DFVSC_CHWRC_RHC:
guid: "453f5dd3-14f4-4d37-aac9-2009345d9761"
description: "Fan coil unit with zone temperature control, return air humidity control and chilled water return air temperature control."
is_canonical: true
implements:
- FCU
- CSP
- DFSS
- DFVSC
- CHWRC
- RHC

FCU_CSP_DFSS_DFVSC_CHWRC_RHC_DAIDC:
guid: "cf43b4e3-b516-491f-9d4b-eaaa37e7e209"
description: "Fan coil unit with zone temperature control, return air humidity control, chilled water return air temperature control and isolation."
is_canonical: true
implements:
- FCU
- CSP
- DFSS
- DFVSC
- CHWRC
- RHC
- DAIDC

FCU_CSP_DX2ZC_ZHC:
guid: "4f6dbf06-0b03-4537-9d53-78855aabea49"
description: "Single zone FCU."
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -406,6 +406,7 @@ DOAS:
- failed_communication_alarm
- smoke_alarm
- filter_alarm
- run_mode
implements:
- EQUIPMENT

Expand Down
23 changes: 22 additions & 1 deletion ontology/yaml/resources/HVAC/entity_types/HX.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -333,4 +333,25 @@ HX_PSWTC_CHWDT_CHWRWISOVM:
- HX
- PSWTC
- CHWDT
- CHWRWISOVPM
- CHWRWISOVPM

HX_SCHWTC_CHWFRM_CWDT:
guid: "7249d972-281a-498a-92b6-2d12ff02e6a2"
description: "Condensing/chilled water heat exchanger with chilled water flowrate monitoring."
is_canonical: true
implements:
- HX
- SCHWTC
- CHWFRM
- CWDT

HX_PSWTC_PWFRM_CWDT_CWSISOVPM:
guid: "94c725f7-e46c-4b41-9c7d-0b44d90f2ef8"
description: "Condensing/process water heat exchanger with process water flowrate monitoring and isolation on condensing return side."
is_canonical: true
implements:
- HX
- PSWTC
- PWFRM
- CWDT
- CWSISOVPM
12 changes: 11 additions & 1 deletion ontology/yaml/resources/HVAC/entity_types/MAU.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -903,6 +903,16 @@ MAU_DFSS2X_DFVSC2X_DXDC_HWDC:
- DXDC
- HWDC

MAU_SFSS_DXSC_SSPC:
guid: "e05424bf-c8c0-40c9-9875-8903dce9bffc"
description: "MAU with supply air static pressure control and supply air temperature control"
is_canonical: true
implements:
- MAU
- SFSS
- DXSC
- SSPC

############################
### Remap These Types ###
############################
Expand Down Expand Up @@ -1099,4 +1109,4 @@ MAU_SFSS_SFVSC_HTSC_BPC_SHM_NONCANONICAL_2:
- MAU_SFSS_SFVSC_HTSC_BPC_SHM
- DEPRECATED
uses:
- humidification_run_command
- humidification_run_command
Loading