Notifications
You must be signed in to change notification settings - Fork 1
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
Showing
8 changed files
with
193 additions
and
6 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,9 @@ | ||
/* | ||
* SPDX-FileCopyrightText: 2024 M5Stack Technology CO LTD | ||
* | ||
* SPDX-License-Identifier: MIT | ||
*/ | ||
/* | ||
To update the unit yourself usage example (UnitCO2) | ||
*/ | ||
#include "main/ComponentOnly.cpp" |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,39 @@ | ||
/* | ||
* SPDX-FileCopyrightText: 2024 M5Stack Technology CO LTD | ||
* | ||
* SPDX-License-Identifier: MIT | ||
*/ | ||
/* | ||
Example of using only unit component without UnitUnified manager | ||
If you use other units, change include files(*1), instances(*2), and get values(*3) | ||
*/ | ||
#include <M5Unified.h> | ||
#include <M5UnitUnified.h> | ||
#include <M5UnitUnifiedENV.h> // *1 Include the header of the unit to be used | ||
|
||
m5::unit::UnitCO2 unit; // *2 Instance of the unit | ||
|
||
void setup() { | ||
M5.begin(); | ||
|
||
auto pin_num_sda = M5.getPin(m5::pin_name_t::port_a_sda); | ||
auto pin_num_scl = M5.getPin(m5::pin_name_t::port_a_scl); | ||
M5_LOGI("getPin: SDA:%u SCL:%u", pin_num_sda, pin_num_scl); | ||
Wire.begin(pin_num_sda, pin_num_scl, 400 * 1000U); | ||
|
||
M5.Display.clear(TFT_DARKGREEN); | ||
if (!unit.assign(Wire) // Assign Wire | ||
|| unit.begin()) { // Begin unit | ||
M5_LOGE("Failed to assign/begin"); | ||
M5.Display.clear(TFT_RED); | ||
} | ||
} | ||
|
||
void loop() { | ||
M5.begin(); | ||
unit.update(); // Explicitly call unit.update() yourself | ||
if (unit.updated()) { | ||
// *3 Obtaining unit-specific measurements | ||
M5_LOGI("CO2:%u Temp:%f Hum:%f", unit.co2(), unit.temperature(), unit.humidity()); | ||
} | ||
} |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,9 @@ | ||
/* | ||
* SPDX-FileCopyrightText: 2024 M5Stack Technology CO LTD | ||
* | ||
* SPDX-License-Identifier: MIT | ||
*/ | ||
/* | ||
To update the unit yourself usage example (UnitCO2) | ||
*/ | ||
#include "main/SelfUpdate.cpp" |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,56 @@ | ||
/* | ||
* SPDX-FileCopyrightText: 2024 M5Stack Technology CO LTD | ||
* | ||
* SPDX-License-Identifier: MIT | ||
*/ | ||
/* | ||
To update the unit yourself usage example (UnitCO2) | ||
If you use other units, change include files(*1), instances(*2), and get values(*3) | ||
*/ | ||
#include <M5Unified.h> | ||
#include <M5UnitUnified.h> | ||
#include <M5UnitUnifiedENV.h> // *1 Include the header of the unit to be used | ||
|
||
m5::unit::UnitUnified Units; | ||
m5::unit::UnitCO2 unit; // *2 Instance of the unit | ||
|
||
void update_task(void*) { | ||
for (;;) { | ||
// If exclusive control is required for access to Wire, insert appropriate controls | ||
unit.update(); // Explicitly call unit.update() yourself | ||
if (unit.updated()) { | ||
// *3 Obtaining unit-specific measurements | ||
M5_LOGI("CO2:%u Temp:%f Hum:%f", unit.co2(), unit.temperature(), unit.humidity()); | ||
} | ||
m5::utility::delay(1); | ||
} | ||
} | ||
|
||
void setup() { | ||
M5.begin(); | ||
|
||
auto pin_num_sda = M5.getPin(m5::pin_name_t::port_a_sda); | ||
auto pin_num_scl = M5.getPin(m5::pin_name_t::port_a_scl); | ||
M5_LOGI("getPin: SDA:%u SCL:%u", pin_num_sda, pin_num_scl); | ||
Wire.begin(pin_num_sda, pin_num_scl, 400 * 1000U); | ||
|
||
auto ccfg = unit.component_config(); | ||
ccfg.self_update = true; | ||
unit.component_config(ccfg); | ||
|
||
M5.Display.clear(TFT_DARKGREEN); | ||
if (!Units.add(unit, Wire) // Add unit to UnitUnified manager | ||
|| !Units.begin()) { // Begin each unit | ||
M5_LOGE("Failed to add/begin"); | ||
M5.Display.clear(TFT_RED); | ||
return; | ||
} | ||
xTaskCreateUniversal(update_task, "update_task", 8192, nullptr, 1, nullptr, APP_CPU_NUM); | ||
} | ||
|
||
void loop() { | ||
M5.begin(); | ||
Units.update(); // unit.update() is not called within this function | ||
M5_LOGI("loop"); | ||
m5::utility::delay(1000); | ||
} |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,13 @@ | ||
/* | ||
* SPDX-FileCopyrightText: 2024 M5Stack Technology CO LTD | ||
* | ||
* SPDX-License-Identifier: MIT | ||
*/ | ||
/* | ||
Simple usage example (UnitCO2) | ||
*/ | ||
#include "main/Simple.cpp" | ||
|
||
|
||
|
||
|
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,40 @@ | ||
/* | ||
* SPDX-FileCopyrightText: 2024 M5Stack Technology CO LTD | ||
* | ||
* SPDX-License-Identifier: MIT | ||
*/ | ||
/* | ||
Simple usage example (UnitCO2) | ||
If you use other units, change include files(*1), instances(*2), and get values(*3) | ||
*/ | ||
#include <M5Unified.h> | ||
#include <M5UnitUnified.h> | ||
#include <M5UnitUnifiedENV.h> // *1 Include the header of the unit to be used | ||
|
||
m5::unit::UnitUnified Units; | ||
m5::unit::UnitCO2 unit; // *2 Instance of the unit | ||
|
||
void setup() { | ||
M5.begin(); | ||
|
||
auto pin_num_sda = M5.getPin(m5::pin_name_t::port_a_sda); | ||
auto pin_num_scl = M5.getPin(m5::pin_name_t::port_a_scl); | ||
M5_LOGI("getPin: SDA:%u SCL:%u", pin_num_sda, pin_num_scl); | ||
Wire.begin(pin_num_sda, pin_num_scl, 400 * 1000U); | ||
|
||
M5.Display.clear(TFT_DARKGREEN); | ||
if (!Units.add(unit, Wire) // Add unit to UnitUnified manager | ||
|| !Units.begin()) { // Begin each unit | ||
M5_LOGE("Failed to add/begin"); | ||
M5.Display.clear(TFT_RED); | ||
} | ||
} | ||
|
||
void loop() { | ||
M5.begin(); | ||
Units.update(); | ||
if (unit.updated()) { | ||
// *3 Obtaining unit-specific measurements | ||
M5_LOGI("CO2:%u Temp:%f Hum:%f", unit.co2(), unit.temperature(), unit.humidity()); | ||
} | ||
} |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters