Releases: psi46/pxar
Releases · psi46/pxar
Stable FullTest with f/w 3.6
Changes to FullTest:
- PH (gain/pedestal) fits with error function instead of tanH
- trimming to VCAL = 35
- vcal scurves taken with ntrig = 50
- (Andrea) DESY bumpbonding test should now work on modules with reasonable run times (not included by default, though)
- (Pirmin) delay a test when running through scripts
- (Vittorio) new version of PH optimization
- (Doug) new faster timing test as part of pretest
- fixed a bug (HV handling) for the baremodule test
- and much more ...
correct VCAL s-curves with increased ntrig
This version corrects the s-curves to dump the VCAL s-curves into SCurveData_C0.dat and increases NTRIG from 5 to 50. This allows a determination of the noise with an error of 0.3 VCAL units.
single-ROC test with first versions of complete x-ray and high-rate tests
Building on release roc2.1-test0-v1.1.0, this release adds the high-rate tests. Note that "high-rate" could currently imply rates below 20MHz.
single-ROC test compatible with MoreWeb
This release is compatible with moreweb. It fixes a few output problems of previous releases. It contains new tests for
- IV characteristics (tested and working on Keithley 2410 at PSI and CERN)
- x-ray setups (not tested for high-rate setups, but working with a low-rate x-ray source)
roc2.1 test software release V1.0
release of test software for ROC V2.1.