Submillimeter fMRI Acquisition using a dual-echo Rosette kspace trajectory at 3T#

Submillimeter fMRI Acquisition using a dual-echo Rosette kspace trajectory at 3T

alt text

We are exploring the utility of the novel 3D dual-echo Rosette kspace MRI for an high-resolution fMRI application.

Mutli Echo MRI = MR(S)I , We look forward to challenging/sharing the novel rosette MR(S)I methods for reproducibility.

alt text

7T, V1 delay in ms, Siemens Scanner super high temporal resolution 2nd echo Regridding, (2soff-2son-2soff, TR=12 ms, Resolution 0.5 mm )

alt text

7T, Siemens Scanner super high temporal resolution 2nd echo Regridding, (2soff-2son-2soff, TR=12 ms, Resolution 0.5 mm )

alt text

alt text

7T, Siemens Scanner super high temporal resolution 2nd echo Regridding

alt text

7T, Siemens Scanner super high temporal resolution 1st echo Regridding

alt text

3T, Siemens Prisma Scanner 1s, 95 petals, 1 petal = 11ms Regridding Comparsion against MB-EPI

alt text

7T, Siemens Terra Scanner 1s, 95 petals, 1 petal = 11ms Regridding

alt text

Resolution insert Measurements: The hole diameter differs between the array pairs: for the left pair it is 1.1 mm, for the center pair it is 1.0 mm, and for the right pair it is 0.9 mm.

Reduced FOV 1st echo echo acquisition time 1s, 95 petals, 1 petal = 11ms Regridding

alt text

2nd echo acquisition time 1s, 95 petals, 1 petal = 11ms Regridding

alt text

1st echo acquisition time 1s, 95 petals, 1 petal = 11ms Compressed Sensing

alt text

First Echo and 2nd Echo with x6 accelaration TR=1300ms

alt text

Subtracion

alt text

First Echo - 2nd Echo

alt text

alt text

RAW DATA

Raw data can be downloadable from the following link.

https://purr.purdue.edu/projects/datasharing4roset/files

Gianna Nossa1, Humberto Monsivais1, Seokkyoon Hong2, Taewoong Park2, Fethi Sila Erdil1, Xin Shen3, Ali Caglar Özen4, Serhat Ilbey4, Mark Chiew5, Cecilia Steinwurzel6, Zoe Kourtzi6, Yen-Yu Ian Shih7, Uzay Emir1,2

1School of Health Sciences, Purdue University, West Lafayette, IN, United States;

2Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, United States;

3Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, United States;

4Department of radiology, Medical Physics, Medical Center-University of Freiburg, Freiburg, Germany; 5University of Toronto;

6Department of Psychology, University of Cambridge;

7Biomedical Research Imaging Center, University of North Carolina Chapel Hill, Chapel Hill, NC, United States

Synopsis

In this study, we overcome the technological barrier against acquiring submillimeter resolution (~ 0.5 mm) fMRI data at 3T via a novel dual-echo Rosette k-space design. This design results in the fine representation of activation maps in two different functional tasks and might be a springboard in neuroimaging by providing very high-resolution spatiotemporal dynamics of neural networks. The method will be further evolved with the feedback from the MRI community via the GitHub platform as such for further acceleration, inflow saturation, and 3D coverage via 3D sampling and/or multiband approaches.

Introduction

Understanding neurological associations have been a challenge in neuroscience, especially the visual pathway. Non-invasive access to functional data through fMRI provides information on the changes in cerebral blood flow and oxygenation in response to stimuli. For a more fine-grained assessment, laminar fMRI measures responses specific to separate cortical layers [1]. Current techniques utilize gradient-recalled echo for functional mapping contrast and image encoding through Echo Planar Imaging [2]. While ultrahigh field strengths (≥7T) generally outperform lower field strengths (3T), the submillimeter resolution is a challenge for high and ultra-high field strengths [3]. We recently demonstrated a novel Rosette k-space design providing improved PSF and SNR compared to radial acquisition and a smooth transition (zero-delay) between the two echoes of dual-echo acquisition [4]. It also offers the potential for further acceleration using higher under-sampling factors and compressed sensing (CS) techniques for reconstruction. In this study, we developed a novel very short TE (VSE) dual-echo Rosette fMRI sequence to capture the submillimeter fMRI signal and compared it against the conventional MB-EPI sequence at 3T.

K-SPACE

alt text

PSF

alt text

SNR

alt text

Methods

The study was approved by the Institutional Review Boards (IRBs) of Purdue University and informed consent was obtained. Two healthy volunteers (M, 40, and 29 years old) underwent brain scans with a whole-body 3T MRI system (Siemens Healthineers, Erlangen, Germany). A vendor-supplied 64-channel receiver head coil was used. For conventional fMRI protocols, we used the 2D CMRR MB-EPI sequence with a multiband acceleration factor of 8, TR = 1.05 s, TE= 46 ms, Slice Thickness = 2 mm, flip angle= 52, number of slices = 72, and nominal in-plane resolution = 1.468 mm. For the novel dual-echo 2D Rosette fMRI sequence, the following acquisition parameters were used: TR = 2.4 s, dual-TEs= 1 and 9 ms, slice thickness = 2, flip angle = 7, number of slices = 1, number of petals with an acceleration factor 4 =189, nominal in-plane resolution = 0.468 mm [4]. Rosette fMRI data were reconstructed with ESPIRiT-based parallel imaging and compressed sensing: l1-wavelets in space and total variation in time using the BART tool (https://github.com/uzayemir/high-resolution-dual-echo-rosette-fmri-) [4]. Two reconstruction resolutions were defined, 0.468 and 0.936 with a final matrix of 512 x 512. Two functional activation paradigms used in this comparison study were an 8-Hz flickering checkerboard and finger tapping for periods of 30 and 15 sec on/off, respectively. FMRI data processing was carried out using FEAT (FMRI Expert Analysis Tool) Version 6.00, part of FSL. Z (Gaussianised T/F) statistic images were thresholded using clusters determined by Z>3.1 and a (corrected) cluster significance threshold of P=0.05 [5].

Results

We demonstrated that the novel dual-echo sequence captures similar activation maps in the occipital and motor cortices in response to functional tasks compared to the conventional MB-EPI sequence (Figures 1 and 2). Additionally, the signal loss in the frontal cortex of MB-EPI is recovered using the VSE dual-echo Rosette, including the eyes (Figure 3).

Figure 1

alt text

Figure 2

alt text

Figure 3

alt text

Discussion and Conclusion

In this study, we demonstrated a novel VSE dual-echo Rosette fMRI sequence and compared it against the MB-EPI sequence. Findings indicate that the novel sequence is capable of detecting functional signals from a submillimeter resolution (~ 0.5 mm in-plane resolution) using clinically and widely available 3T scanners. The improvements to accelerate the acquisition and increase the 3D coverage will be presented and discussed. The novel VSE dual-echo Rosette fMRI sequence might be a springboard in neuroimaging by providing a very high-resolution spatiotemporal dynamics of neural networks.

References

[1]. Lawrence SJ, Formisano E, Muckli L, de Lange, FP. Laminar fMRI: Applications for cognitive neuroscience. Neuroimage. 2019;197,785-791.

[2]. Ugurbil K. What is feasible with imaging human brain function and connectivity using functional magnetic resonance imaging. Philos Trans R Soc B Biol Sci. 2016;371(1705). doi:10.1098/RSTB.2015.0361

[3]. Toi PT, Jang HJ, Min K, et al. In vivo direct imaging of neuronal activity at high temporospatial resolution. Science (80- ). 2022;378(6616):160-168. doi:10.1126/SCIENCE.ABH4340

[4]. Shen X, Özen AC, Sunjar A, et al. Ultra-short T2 components imaging of the whole brain using 3D dual-echo UTE MRI with rosette k-space pattern. Magn Reson Med. Published online September 25, 2022. doi:10.1002/MRM.29451

[5]. Worsley KJ. Testing for signals with unknown location and scale in a χ2 random field, with an application to fMRI. Adv Appl Probab. 2001;33(4):773-793. doi:10.1239/AAP/1011994029

RAW DATA

Raw data can be downloadable from the following link.

https://purr.purdue.edu/projects/datasharing4roset/files

alt text

About

Submillimeter fMRI Acquisition using a dual-echo Rosette kspace trajectory at 3T

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages